Configurable control for more VAV applications: one predefined
terminal application, flexible hardware, and less manual setup
on every job.
The LOYTEC VAV solution combines a predefined Terminal Unit Application with flexible terminal-control hardware. Available through Delta IBT Distribution Partners, it helps integrators cover more box types with one familiar application and less manual setup.
Default parameters and automatic I/O allocation help reduce commissioning labor. Dedicated balancing access lets the TAB contractor work independently, while software reassignment of compatible I/O helps avoid physical rewiring.
Proven with LOYTEC partners and OEMs, including successful US installations, the application is now available through Distribution.
Security built into the connection: BACnet/SC adds encrypted, authenticated communication.
Flexible network connections Support BACnet/IP and BACnet/SC. Routing between IP and SC supports flexible network design.
BACnet into the BAS Exposed BACnet objects support eWEB and compatible building-management platforms. Consistent BACnet IDs simplify point mapping.
OPC into LWEB-900 OPC XML-DA and OPC UA connect the application to LWEB-900, with existing templates and graphics for a consistent supervisory experience.
Connected at the system. In control at the box.The terminal sequence continues when the supervisory network is offline, and coordinates zone requests with the LOYTEC AHU application.
Nine predefined configurations across cooling, parallel fan, series fan and dual-duct boxes.
Defaults, automatic I/O mapping and device detection simplify setup. Reassign compatible points in software.
Provide dedicated BalanceTool access, or balance through an L-STAT when fitted and enabled.
BACnet/IP and BACnet/SC support BAS integration, including eWEB. OPC connects to LWEB-900.
| LIOB-585 VAV | LIOB-595 VAV | Inputs | 6 universal inputs | 5 application inputs |
|---|---|---|
| Outputs | 2 analog, 5 TRIAC | 1 analog, 4 relay |
| Typical fit | Fan-speed control with modulating reheat, or a fan plus four reheat stages | Relay outputs or local sensor power to suit the job |
| Application | LOYTEC VAV Terminal Unit Application, nine predefined configurations | |
| Network | BACnet/IP and BACnet/SC; OPC XML-DA and OPC UA to LWEB-900 | |
Start with a predefined application instead of developing each terminal sequence from scratch. Defaults and automatic I/O allocation help reduce commissioning labor, while software reassignment helps resolve compatible I/O errors without rewiring.
Defaults that save setup
Set the box type and style, then adapt project settings. Automatic detection of L-STAT and MP-Bus devices reduces manual point assignment.
I/O that adapts to the job
Move a point to another suitable channel in software to help avoid a return to physical wiring.
End User License & Prohibited End-Use Terms